non/Mixer/Meter_Indicator_Module.C

271 lines
6.5 KiB
C
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

/*******************************************************************************/
/* Copyright (C) 2009 Jonathan Moore Liles */
/* */
/* This program is free software; you can redistribute it and/or modify it */
/* under the terms of the GNU General Public License as published by the */
/* Free Software Foundation; either version 2 of the License, or (at your */
/* option) any later version. */
/* */
/* This program is distributed in the hope that it will be useful, but WITHOUT */
/* ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or */
/* FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for */
/* more details. */
/* */
/* You should have received a copy of the GNU General Public License along */
/* with This program; see the file COPYING. If not,write to the Free Software */
/* Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA. */
/*******************************************************************************/
#include "Meter_Indicator_Module.H"
#include <stdio.h>
#include <FL/Fl.H>
#include <FL/Fl_Value_Slider.H>
#include <FL/Fl_Box.H>
#include <FL/fl_draw.H>
#include <FL/Fl_Counter.H>
#include <FL/Fl_Light_Button.H>
#include "FL/Boxtypes.H"
#include "FL/Fl_Arc_Dial.H"
#include "FL/Fl_Labelpad_Group.H"
#include "FL/Fl_Scalepack.H"
#include "Engine/Engine.H"
#include "Chain.H"
#include "DPM.H"
#include "FL/test_press.H"
const float CONTROL_UPDATE_FREQ = 0.1f;
Meter_Indicator_Module::Meter_Indicator_Module ( bool is_default )
: Module ( is_default, 50, 100, name() )
{
box( FL_NO_BOX );
_pad = true;
control = 0;
control_value = 0;
add_port( Port( this, Port::INPUT, Port::CONTROL ) );
dpm_pack = new Fl_Scalepack( x(), y(), w(), h() );
dpm_pack->type( FL_HORIZONTAL );
control_value = new float[1];
*control_value = -70.0f;
end();
clear_visible_focus();
Fl::add_timeout( CONTROL_UPDATE_FREQ, update_cb, this );
}
Meter_Indicator_Module::~Meter_Indicator_Module ( )
{
if ( control_value )
{
delete[] control_value;
control_value = NULL;
}
Fl::remove_timeout( update_cb, this );
log_destroy();
}
void
Meter_Indicator_Module::get ( Log_Entry &e ) const
{
Port *p = control_input[0].connected_port();
Module *m = p->module();
e.add( ":module", m );
e.add( ":port", m->control_output_port_index( p ) );
Module::get( e );
}
void
Meter_Indicator_Module::set ( Log_Entry &e )
{
Module::set( e );
int port = -1;
Module *module = NULL;
for ( int i = 0; i < e.size(); ++i )
{
const char *s, *v;
e.get( i, &s, &v );
if ( ! strcmp( s, ":port" ) )
{
port = atoi( v );
}
else if ( ! strcmp( s, ":module" ) )
{
int i;
sscanf( v, "%X", &i );
Module *t = (Module*)Loggable::find( i );
assert( t );
module = t;
}
}
if ( port >= 0 && module )
control_input[0].connect_to( &module->control_output[port] );
}
void
Meter_Indicator_Module::update_cb ( void *v )
{
((Meter_Indicator_Module*)v)->update_cb();
}
void
Meter_Indicator_Module::update_cb ( void )
{
Fl::repeat_timeout( CONTROL_UPDATE_FREQ, update_cb, this );
if ( control_input[0].connected() )
{
// A little hack to detect that the connected module's number
// of control outs has changed.
Port *p = control_input[0].connected_port();
if ( dpm_pack->children() != p->hints.dimensions )
{
/* engine->lock(); */
dpm_pack->clear();
control_value = new float[p->hints.dimensions];
for ( int i = p->hints.dimensions; i--; )
{
DPM *dpm = new DPM( x(), y(), w(), h() );
dpm->type( FL_VERTICAL );
align( (Fl_Align)(FL_ALIGN_CENTER | FL_ALIGN_INSIDE ) );
dpm_pack->add( dpm );
control_value[i] = -70.0f;
dpm->value( -70.0f );
}
/* engine->unlock(); */
}
else
{
for ( int i = 0; i < dpm_pack->children(); ++i )
{
((DPM*)dpm_pack->child( i ))->value( control_value[i] );
}
}
}
// redraw();
}
void
Meter_Indicator_Module::connect_to ( Port *p )
{
control_input[0].connect_to( p );
DPM *o = new DPM( x(), y(), this->w(), h() );
o->type( FL_VERTICAL );
align( (Fl_Align)(FL_ALIGN_CENTER | FL_ALIGN_INSIDE ) );
dpm_pack->add( o );
}
int
Meter_Indicator_Module::handle ( int m )
{
switch ( m )
{
case FL_PUSH:
{
if ( test_press( FL_BUTTON1 ) )
{
/* don't let Module::handle eat our click */
return Fl_Group::handle( m );
}
return Module::handle( m );
}
}
return Module::handle( m );
}
void
Meter_Indicator_Module::handle_control_changed ( Port *p )
{
THREAD_ASSERT( UI );
/* The engine is already locked by the UI thread at this point in
the call-graph, so we can be sure that process() won't be
executed concurrently. */
if ( p->connected() )
{
p = p->connected_port();
if ( dpm_pack->children() != p->hints.dimensions )
{
dpm_pack->clear();
control_value = new float[p->hints.dimensions];
for ( int i = p->hints.dimensions; i--; )
{
DPM *dpm = new DPM( x(), y(), w(), h() );
dpm->type( FL_VERTICAL );
align( (Fl_Align)(FL_ALIGN_CENTER | FL_ALIGN_INSIDE ) );
dpm_pack->add( dpm );
control_value[i] = -70.0f;
dpm->value( -70.0f );
}
}
}
}
/**********/
/* Engine */
/**********/
void
Meter_Indicator_Module::process ( void )
{
if ( control_input[0].connected() )
{
Port *p = control_input[0].connected_port();
for ( int i = 0; i < p->hints.dimensions; ++i )
control_value[i] = ((float*)control_input[0].buffer())[i];
}
}