base: push the mode down to the TuhiDevice

A device isn't registered or not, it's merely in a *state* of being
registering or not. Pass the current mode down to the TuhiDevice instead of a
boolean for 'registered'. The 'registered' gobject property is left in-place
for now, the dbus server needs it.
pull/70/head
Peter Hutterer 2018-02-12 10:29:56 +10:00 committed by Benjamin Tissoires
parent 720955db7c
commit ad0e81b395
1 changed files with 24 additions and 12 deletions

View File

@ -51,13 +51,13 @@ class TuhiDevice(GObject.Object):
BATTERY_UPDATE_MIN_INTERVAL = 300
def __init__(self, bluez_device, config, uuid=None, registered=True):
def __init__(self, bluez_device, config, uuid=None, mode=DeviceMode.LISTEN):
GObject.Object.__init__(self)
self.config = config
self._wacom_device = None
# We need either uuid or registered as false
assert uuid is not None or registered is False
self.registered = registered
assert uuid is not None or mode == DeviceMode.REGISTER
self._mode = mode
self._battery_state = TuhiDevice.BatteryState.UNKNOWN
self._battery_percent = 0
self._last_battery_update_time = 0
@ -69,12 +69,18 @@ class TuhiDevice(GObject.Object):
self._tuhi_dbus_device = None
@GObject.Property
def registered(self):
return self._registered
def mode(self):
return self._mode
@registered.setter
def registered(self, registered):
self._registered = registered
@mode.setter
def mode(self, mode):
if self._mode != mode:
self._mode = mode
self.notify('registered')
@GObject.Property
def registered(self):
return self.mode == DeviceMode.LISTEN
@GObject.Property
def name(self):
@ -166,6 +172,10 @@ class TuhiDevice(GObject.Object):
pass
def _on_register_requested(self, dbus_device):
# FIXME: this needs to throw an exception/return the value
if self.mode == DeviceMode.LISTEN:
return
self.register()
def _on_drawing_received(self, device, drawing):
@ -184,7 +194,10 @@ class TuhiDevice(GObject.Object):
def _on_uuid_updated(self, wacom_device, pspec, bluez_device):
self.config.new_device(bluez_device.address, wacom_device.uuid, wacom_device.protocol)
self.registered = True
# FIXME: we have registered and that *should* set us to listen. But
# the ManufacturerData doesn't update until (some time into) the
# next connection request.
self.mode = DeviceMode.LISTEN
def _on_listening_updated(self, dbus_device, pspec):
self.notify('listening')
@ -309,8 +322,7 @@ class Tuhi(GObject.Object):
# create the device if unknown from us
if bluez_device.address not in self.devices:
d = TuhiDevice(bluez_device, self.config, uuid=uuid,
registered=(mode == DeviceMode.REGISTER))
d = TuhiDevice(bluez_device, self.config, uuid, mode)
d.dbus_device = self.server.create_device(d)
d.connect('notify::listening', self._on_listening_updated)
self.devices[bluez_device.address] = d
@ -318,7 +330,7 @@ class Tuhi(GObject.Object):
d = self.devices[bluez_device.address]
if mode == DeviceMode.REGISTER:
d.registered = False
d.mode = mode
logger.debug(f'{bluez_device.objpath}: call Register() on device')
elif d.listening:
d.listen()