Commit Graph

192 Commits (b16a16abde7bf21a7f2184651c8531d8484c49c9)

Author SHA1 Message Date
Peter Hutterer b16a16abde Add a SyncState signal to the DBus interface
Propagated whenever we start talking to the device (and then again when we
stop). The purpose of this signal is merely that a UI can show e.g. a progress
bar while we're talking to the device to ensure the user something is
happening.

Fixes #138
2019-07-15 09:38:19 +02:00
Peter Hutterer 05fd213940 wacom: fetch the battery state during register
Any decent UI will want to know this given the device is online right now.

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2019-07-15 09:38:19 +02:00
Peter Hutterer f488d4e130 wacom: make 0xb3 the expected opcode
Virtually all the commands we have that don't have a specific opcode expect
0xb3. Since that's the general ACK command, we can default to that and make
everything else the exception.

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2019-07-15 09:38:19 +02:00
Peter Hutterer a061240b11 base: once the device is registered, we're done
This method is called whenever a bluez property changes, don't prompt the user
(in the logs) to register the device we just finished registering.
2019-07-15 09:38:19 +02:00
Peter Hutterer de3386a88d base: add a helpful comment
This it's more obvious that add_device can really be called every second or so
2019-07-15 10:43:35 +10:00
Peter Hutterer 6aced355b5 wacom: minor change to a debug message 2019-07-15 10:43:35 +10:00
Peter Hutterer 72507b687a wacom: remove some superfluous ''' 2019-07-15 10:43:35 +10:00
Peter Hutterer caa52e0c51 base: when search is turned off, remove unregistered devices again
This is what the dbusserver module does as well, so we end up with a weird
mismatch: to the base module the device is still known and unregistered on the
next search start. So when we see the bluez properties float past, we don't
add a new devices.

To the dbusserver the device is gone though and since we don't add it again in
the base module, we never send a signal for it.

Since there's a reasonable assumption that if we don't register the device, we
don't want it anyway, let's delete it from the base device list too.

This doesn't fix the issue of a device timing out while waiting for a button
press. That device will count as known until the next search stop. But at
least now we don't have to restart tuhi.

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2019-07-08 10:52:39 +02:00
Peter Hutterer 6ff9f34d08 wacom: fix type error when registering a Intuos Pro paper
gmtime() and localtime() both take seconds, not a struct time.
2019-07-08 10:52:39 +02:00
Peter Hutterer 0ddc33a37b drawing: fix deprecation warning
tuhi/drawing.py:46: PyGIDeprecationWarning: GObject.property is deprecated;
use GObject.Property instead
  @GObject.property

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2019-06-07 15:35:59 +10:00
Daniel Martin b52891f8fd ble: prefix all device logs with address
Use a logger child in BlueZDevice prefixing all log messages with the
device address.

Signed-off-by: Daniel Martin <consume.noise@gmail.com>
2019-06-07 08:34:07 +10:00
Daniel Martin c719ecf2e2 ble: use properties instead of variables
Replace variables (objpath, interface, uuid) with properties.

Signed-off-by: Daniel Martin <consume.noise@gmail.com>
2019-06-07 08:34:07 +10:00
Daniel Martin 7f9e58e587 ble: simplify GATT characteristic lookup
No need to get triggered by BlueZDeviceManager when it finds any GATT
characteristic. The BlueZDevice just needs its 'ServicesResolved' and
can resolve the GATT characteristics itself.

This solves a FIXME.

Signed-off-by: Daniel Martin <consume.noise@gmail.com>
2019-06-07 08:34:07 +10:00
Daniel Martin e7f8cc2bc2 ble: make object manager return sorted object list
The object list returned by object managers get_objects() function is
not sorted. Though, we rely on objects being sorted by their object
path.

Replace the object managers get_objects() function with a variant
fixing that. Additionally, our variant makes it possible to filter
the returned object list by object path and interface.

Examples:

- get_objects():
  /
  /org/bluez
  /org/bluez/hci0
  /org/bluez/hci0/dev_00_00_00_00_00_00
  /org/bluez/hci0/dev_00_00_00_00_00_00/service0000
  /org/bluez/hci0/dev_00_00_00_00_00_00/service0000/char0000
  /org/bluez/hci0/dev_00_00_00_00_00_00/service1111
  /org/bluez/hci0/dev_00_00_00_00_00_00/service1111/char1111
  /org/bluez/hci0/dev_FF_FF_FF_FF_FF_FF
  /org/bluez/hci0/dev_FF_FF_FF_FF_FF_FF/serviceffff
  /org/bluez/hci0/dev_FF_FF_FF_FF_FF_FF/serviceffff/charffff

- get_objects(interface='org.bluez.Adapter1'):
  /org/bluez/hci0

- get_objects(interface='org.bluez.GattCharacteristic1'
              base_path='/org/bluez/hci0/dev_00_00_00_00_00_00'):
  /org/bluez/hci0/dev_00_00_00_00_00_00/service0000/char0000
  /org/bluez/hci0/dev_00_00_00_00_00_00/service1111/char1111

Signed-off-by: Daniel Martin <consume.noise@gmail.com>
2019-06-07 08:34:07 +10:00
Peter Hutterer 1b9b7760fd wacom: let's assume any 0xb3 with nonzero data is an error
b3 01 00 seems to be a generic "I'm happy" and the few others we've seen
are errors. So let's encode that and reconsider if it turns out to be false.

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2019-06-05 11:14:48 +02:00
Peter Hutterer c1283289b7 wacom: sort the error handling
and use elif for clarity (even though we have exceptions here)

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2019-06-05 11:14:48 +02:00
Peter Hutterer 4b02a6f51c Fix flake8-3 complaints
Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2019-06-05 10:58:21 +02:00
Peter Hutterer 82b81b1c34 base: add timestamps to the logs
Fixes #127

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2019-06-05 10:54:44 +02:00
Ishak BELAHMAR f2263e72cf wacom/live: read Slate dimensions before starting live mode 2019-05-03 09:56:20 +02:00
Benjamin Tissoires c21c8a4633 wacom: do not use relative data when exporting
we already are keeping a record of the x,y and p. So we are trying
to duplicate the effort by using new_rel.
The problem is that some reports have relative coordinates but absolute
pressure data. Which means we are missing the pressure change as it has
a relative value of 0.

By trusting the wacom internal state, we can have the json data that
matches it completely.
2019-04-29 09:36:11 +02:00
Benjamin Tissoires 6d74615085 tuhi: prettify the exported json
having the whole file in a single line is fine for programs, much
less for humans
2019-04-29 09:36:11 +02:00
Peter Hutterer 7e751d45c8 base: if gi.repository fails to import, warn
We need python 3.6 but old Ubuntus only have 3.5. 3.6 can be installed (and
thus we get past the 3.6 sys.version check), but the gi.repository backports
are in various states of disarray (see #103 and #104).

And Python (and in particular gi) makes it hard for users to distinguish
between "the dependencies are a mess" and "this is a bug in tuhi".

So let's catch any error during gi.repository import and print a warning to
the user, in the hope of getting less bugs caused by Ubuntu frankenpythons.
Still won't fix issues like #104, but I'm not sure how to test for those
errors.

Related to #103
2018-03-06 09:33:17 +01:00
Peter Hutterer caf1264952 dbus: add file format version negotiation for the JSON data
Export the supported versions in a Manager property and require the client to
request a specific version in GetJSONData. Without that, the server could
never update the format and clients would have to support every single
historical version to make sure they can run against any version server.

Fixes #98
2018-02-19 11:17:18 +10:00
Peter Hutterer d4ea6e3938 dbus: change the JSON timestamp argument to 64 bit
Because we're totally going to ship tuhi in embedded devices that are going to
be in use until after 2038 when time resets to zero, the world goes big bang
and the only survivers will be 64-bit species. Or something like that. Either
way, the API documentation already said so anyway and the DrawingsAvailable
property is already 64 bit too.

Semi-confusingly: the dbus 64 bit unsigned type is 't', it doesn't stand for
'timestamp'.
2018-02-19 11:16:27 +10:00
Benjamin Tissoires 789c098e82 wacom: do not timeout on long drawing retrievals
It can easily take more than 5 seconds when reading the data. The current
timeout just cuts the connection while it is still reading.

We *could* just remove the timeout here as the device will gracefully
send us a 0xc8 opcode with a blank CRC if we shut the device down while
retrieving the data.

However, better being on the safe side and keep a timeout, but restart it
if we are still getting pen data during the timeout.

Fixes #91
2018-02-16 10:52:49 +01:00
Benjamin Tissoires a5cb084a31 wacom: use semaphore instead of polling
Using polling is bad, true, but it worked. However, using a Semaphore
is better and we can directly benefit from the internal timeout
implementation.
2018-02-16 10:51:09 +01:00
Benjamin Tissoires be2ac9fed3 wacom/live: take into account 'physical' borders of the bloc of paper
When using the live mode on the Slate, the bloc note actually hampers
the pen and prevents it to address all of the pixels on the screen.

Add some artificial boundaries that roughly match the primary design
of the device.

The Intuos Pro has a clip where you put a regular sheet of paper, so there
is no point restraining the active surface.

Fixes #88
2018-02-16 10:47:19 +01:00
Benjamin Tissoires 013de2a6e4 wacom/live: do not fetch the width and height, rely on stored values
It's not like we are handling hundreds of devices. And this allows us to
be more flexible in which fields are replaced in the report descriptor.
2018-02-16 10:47:19 +01:00
Benjamin Tissoires cf4d5b184e wacom/live: make the pressure dependent of the class
The Intuos Pro has 4096 levels of pressure, while the Slate and the Spark
only has 2048. We should do something about it.
2018-02-16 10:47:19 +01:00
Benjamin Tissoires 18221dfd58 wacom/live: fix physical maximums
This way, udevadm shows on the Slate:
E: ID_INPUT_HEIGHT_MM=148
E: ID_INPUT_TABLET=1
E: ID_INPUT_WIDTH_MM=216

Fixes #84
2018-02-16 10:47:19 +01:00
Benjamin Tissoires ee15b474fd wacom/live: make sure the kernel assigns INPUT_PROP_POINTER
The wacom kernel driver assigns INPUT_PROP_DIRECT if we use the
application Pen. Using the Digitizer one fixes that.
2018-02-16 10:47:19 +01:00
Peter Hutterer 7b246e0892 wacom: add packet handling of the two initial packets the IntuosPro sends
One is a fixed header, one  is the stroke timestamp
2018-02-16 15:43:28 +10:00
Peter Hutterer 31ab5f37d3 wacom: move stroke prefix handling into a packet handler 2018-02-16 15:43:28 +10:00
Peter Hutterer 5692a1f3b2 wacom: add PacketHandlers for handling special commands
For data packets other than basic motion/pressure strokes, add a PacketHandler
that can deal with that particular packet. Those handlers are part of the
class declaration, when we instantiate a protocol we pull them all into a
packet_handlers list and go through them. The first one to return True is
considered the right handler and we expect something has been done with the
packet.

This patch includes the handlers for the end-of-stroke and end-of-sequence
packets, the rest to be added later.
2018-02-16 15:43:28 +10:00
Peter Hutterer 43064b58fc wacom: add a WacomPacket class
Instad of carrying around a lot of parameters, move this into a class with
properties. Eventually we can subclass that one for the special opcodes (or
something...)
2018-02-16 15:43:28 +10:00
Peter Hutterer 23e18cea67 drawing: add a stroke.seal() functionality
Makes end-of-stroke handling easier, we can call seal() on the current stroke
and it'll make drawing.current_stroke() None, which is something we can deal
with.
2018-02-16 15:43:28 +10:00
Peter Hutterer 155a11104c wacom: print an error if our device is more than 5 mins out 2018-02-16 15:43:28 +10:00
Peter Hutterer 09bfe44dd7 drawing: rename the stroke from 'l' to 's'
Leftover copy/paste error from when this class had a Layer subclass
2018-02-16 15:43:28 +10:00
Peter Hutterer 9fbfe17e13 ble: disable a debug message
Now that we got the basics running and reliable, this debug message is mostly
just noise, especially when in an office with lots of bluetooth devices
around. Comment it out, to be enabled when necessary.
2018-02-16 15:43:28 +10:00
Benjamin Tissoires 17dc80bea3 wacom: fix report descriptor logical min/max
Changing the python representation is not enough. We also need to change
the HID marker with the correct size.

Fixes 67b4d2b8fe
2018-02-14 13:11:37 +01:00
Peter Hutterer 67b4d2b8fe wacom: allow 4 bytes for width/height
Intuos Paper needs more than 16 bits

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2018-02-14 15:52:34 +10:00
Peter Hutterer 138497a73b wacom: add support for the Intuos Pro 2 paper 2018-02-14 15:03:02 +10:00
Peter Hutterer 7796d3c110 wacom: don't add points to the log until we have an absolute value
On the Intuos Pro at least we sometimes get events that are all relative at
first and it can take several events for us to have all three values as
absolute. This is likely a parsing error on our side, but meanwhile don't
write the data until we have at least one known value for all three axes.

And because the SVG writer isn't happy with empty strokes, add a seal()
function to the drawing to purge empty strokes.

Fixed #92 or at least works around it
2018-02-14 14:54:17 +10:00
Peter Hutterer 6c156efc01 wacom: make relative/abs events more obvious in the log
Mark the deltas with a * if they're the ones that changed.
2018-02-14 14:50:49 +10:00
Peter Hutterer 80d0066cef wacom: we only have one drawing per exchange
skip putting a single drawing in a list
2018-02-14 14:50:49 +10:00
Peter Hutterer c39b735e1e wacom: factor out the 'next stroke data' parsing 2018-02-14 14:50:49 +10:00
Peter Hutterer 8ecc397303 wacom: skip over the prefix when handling pen data
The prefix (4 bytes on the spark/slate) is some data that we don't know yet.
It *could* be the size of a tablet/drawing in LE byte order: 14434x29794
although that doesn't quite match the Intuos Pro data where the prefix is
different.

Either way, having this be an opcode of 0x3800 was probably just coincidence.
Let's skip over the header normally and assume that once we have a prefix, we
have a drawing. This opcode never occurs a second time within the same
drawing.
2018-02-14 14:50:49 +10:00
Peter Hutterer 876f35f806 wacom: factor out the prefix handling
The Intuos Pro has a different prefix, we'll need to override this. Dropping
the comment about the 8bt, on the intuos pro the prefix is nonsensical so
let's not leave a false lead there.
2018-02-14 14:50:45 +10:00
Peter Hutterer 726362107b wacom: append multiple nordic answers to each other
On the Spark, the 0xc9 CRC comes almost immediately after the 0xc8
end-of-sequence. This causes a race condition where sometimes we process the
0xc8 before the 0xc9 arrives, other times the 0xc9 overwrites the current
nordic_answer value before we get to it - triggering an unexpected opcode
exception.

Fix this by appending the nordic answer and only ever pulling off enough to
satisfy the current request.

Fixes #90
2018-02-14 11:25:13 +10:00
Peter Hutterer 240b982070 wacom: fix Spark CRC check
All it needs is less reversing
2018-02-14 11:25:13 +10:00