This makes our signal handler useless and leads to infinite SIGSEGV
loops because the ev callback handler gets called only from within the
event loop, and control doesn’t necessary get to the event loop…
This reverts commit 514265b529.
If there is a single floating con on a separate workspace that is not
focused, and this con becomes urgent, switching back to that workspace
may result in a crash of i3. This is because while setting the urgency
of parent containers, 'parent' may become NULL in case of floating
containers. This commit checks the validity of parent.
fixes#821
We need to verify that setting the event mask works, and we need to
include StructureNotify to get unmap events at any point in time.
Thanks darkraven for the pointer.
fixes#718
Previously, when you had an urgent container in a stack on some
invisible workspace (say urxvt) and you switched to it, the urgency hint
was not properly cleared.
Previously, i3 would send width=0, height=0 to windows which were put on
workspaces created by an assignment (that is, invisible workspaces,
which do not get rendered normally).
fixes#653
The removed code was add by commit 61b8a62 to fix#564. That bug is cause
by rendering the mplayer window again as a floating window (even if it
has been rendered before as a fullscreen window, at line 202). So simply
checking for fullscreen window is enough to solve this problem. Treating
floating/tiling fullscreen window differently is not needed.
A good visualization of the new algorithm is this:
+--------+
| |
+--------+=| S1 |========================
| | | |
| S0 | +--------+
| | +--------+
+--------+=========| |================
| S2 | +--------+
| | | |
+--------+ | S3 |
| |
+--------+
When focus is on S0, 'focus output right' will first match S1 (the
closest output which overlaps in the highlighted area), then S2, but not
S3 (since S3 does not overlap into the highlighted area).
fixes#669fixes#771
We now wait for the child process to send the first line before stopping
it to use the signal which might be specified in the i3bar protocol
header
Since clients might use the same signal for both stop and cont, we also
save the stopped state of the child to avoid stopping it while hidden!
While it’s certainly better and clearer to specify it, we should do the
right thing when the unit is missing, just like CSS for example
(margin: 0; is okay, margin: 0px; too).
If there is a client with an urgency hint on another workspace and
switching to this workspace would cause the urgency to be reset (by
moving the focusing to the client), delay the reset by some time. This
gives the user the chance to see it.
This commit adds the possibility to configure the urgency delay timer
duration using the 'force_display_urgency_hint' directive. Also,
documentation and a testcase was added to allow for automated checks of
the intended behavior.
fixes#482
this implements both the "move container to workspace back_and_forth" command
and movements to the same workspace when auto_back_and_forth is set.
it includes documentation and test suite additions by michael.
it also simplifies the workspace_show_by_name function (making use of
workspace_get accepting NULL pointers).
Introducing a new event to subscribe called mode. It's fired up
when i3 changes binding mode (like switching from default to resize).
IPC guide adjusted also.
Functions such as fprintf() might be unsafe to use in a signal handler,
see http://stackoverflow.com/questions/3941271/#answer-3941563
By using ev_signal, libev will use a tiny signal handler which just
passes on the information and then calls (outside of the signal handler)
our callback function which can use fprintf() and other unsafe
functions.
fixes#803