If input focus is set by the window manager, it is not necessary to send
WM_TAKE_FOCUS because it has already taken focus.
http://tronche.com/gui/x/icccm/sec-4.html#s-4.1.7
> The goal is to support window managers that want to assign the input
> focus to a top-level window in such a way that the top-level window
> either can assign it to one of its subwindows or can decline the offer
> of the focus. For example, a clock or a text editor with no currently
> open frames might not want to take focus even though the window
> manager generally believes that clients should take the input focus
> after being deiconified or raised.
Both setting input focus and sending WM_TAKE_FOCUS is effectively
setting focus on the window twice which is certainly against the spirit
of the spec, if not the letter.
fixes#1167
Add and update the _NET_CLIENT_LIST property on the root window to
better comply with ewmh standards.
Information on this property can be found here:
http://standards.freedesktop.org/wm-spec/latest/ar01s03.html
> These arrays contain all X Windows managed by the Window Manager.
> _NET_CLIENT_LIST has initial mapping order, starting with the oldest window.
fixes#1099
BAIL_OUT produces a friendlier message explaining why the tests cannot
continue on the command line. `die` produces a cryptic message that some
test failed for some reason.
cmd_resize does not implement a method to resize dock clients.
A command like `[instance=".*"] resize grow width 160 px or 16 ppt`
when a dock client matched would crash i3.
fixes#1201
This patch fixes ticket #1168 to extend the window IPC event mechanism
to send IPC events for window focus and title changes. The newly added
window events use the same format as the already established "new"
event.
Specifically this patch:
* Moves the ipc_send_window_event() function from src/manage.c into
src/ipc.c and adds an argument for the change property of the event
* Updates src/manage.c to use the new function signature. To ensure
that the "new" event does not send the same event data as the
"focus" event, setting focus now happens after the "new" event
has been sent
* Adds IPC focus event notification to src/x.c. To workaround a problem
during window close when accessing the window name, a function has been
added to query whether a window is actually attached to its parent. To
avoid obsolete focus notification, a new field has been added to keep
track of the focus without any interference by the click handling
* Adds IPC title event notification to src/handlers.c. To avoid
obsolete title notification, a function has been added to determine
whether a window title has actually changed
* Updates the IPC documentation to include the new events
* Updates testcases/t/205-ipc-windows.t to include the "focus" event
in order to ensure the correct event sequence
* Adds two new unit tests, b/testcases/t/219-ipc-window-focus.t and
b/testcases/t/220-ipc-window-title.t to ensure proper "focus" and
"title" events
To be honest, I’m not entirely sure where the race condition originates
from, but when making sure that there are no pending events
(which is what sync_with_i3 accomplishes) before warping the pointer, we
have less flaky testsuite runs.
closes#1189
This hopefully increases the reliability of the test. Empty containers
created by “open” sometimes get spurious UnmapNotify events, and in at
least one run, this test failed because of such an event.
Calls ewmh_update_current_desktop on startup to set the
_NET_CURRENT_DESKTOP property. Without this change the property only
gets set after the workspaces have been manipulated. Also exclude
hidden workspaces (i.e. those starting with "__" from the workspace
index.
Adds tests for startup and workspace switching.
Make sure the command `move <direction>` properly sends the workspace
focus ipc event required for i3bar to be properly updated and redrawn.
Make `ipc_send_workspace_focus_event publicly available from ipc.h for
more flexible event sending.
Change the behavior of movement into a branch with respect to the
position the moving con will be placed within the branch when the
movement is complete.
The correct position is determined by the direction of movement or the
position of the focused-inactive container within the branch.
If the direction of movement is the same as the orientation of the
branch container, append or prepend the container to the branch in the
obvious way. If the movement is to the right or downward, insert the
moving container in the first position (i.e., the leftmost or top
position resp.) If the movement is to the left or upward, insert the
moving container in the last position (i.e., the rightmost or bottom
position resp.)
If the direction of movement is different from the orientation of the
branch container, insert the container into the branch after the
focused-inactive container.
fixes#1060
Split test 514's assertion into three assertions to make it more
explicit what is being tested, and why a run might fail.
Move critical test code out of the event handler to clarify flow and
allow a query of the actual current workspace to use in assertions.
Works around an issue which caused this test to fail spurriously because
of pointer-related quirks in the i3 test suite which would sometimes
cause i3 to open on workspace 2 (However, the test is now agnostic to
the initial workspace or output).
When 'move <direction>' is issued in the context of a container that
borders a workspace, and there is no suitable place within this
workspace for which this container can move, move the container to the
closest output in this direction instead.
When focusing/moving to outputs, the method of getting the correct
output for a given container fails if the container in question is
floating and only partially mapped on an output screen. This patch
introduces a fail-safe retrieval of the output for any container.
When i3 begins to manage a window, if the window opens on a workspace
that is not visible, the urgency hint on the newly managed window will
be set.
fixes#1088
i3 would accept an invalid resize command like 'resize shrink width 10
px or' without specifying the ppt value, and then crash. This patch
fixes the parser specification.
i3 current behavior hides the binding mode indicator when
workspace buttons are disabled.
This patch adds a new configuration for i3bar called
'binding_mode_indicator' which acts like the workspace_buttons.
It is now possible to configure i3bar to hide the
workspace buttons and keep showing the binding mode indicator.
This should make the hide workspace buttons configuration
more convenient for those who are heavily using binding
modes.
Default value for binding_mode_indicator is true.
If the currently focused window is in fullscreen mode, and a new window
is opened with WM_STATE_FULLSCREEN set, the new window now becomes the
new fullscreen window and gains focus.
Add debuglog command that takes toggle|on|off. Add get_debug_logging()
to be able to toggle. Make t/187-commands-parser.t expect 'debuglog'.
Document the debuglog command in userguide.