Commit Graph

578 Commits

Author SHA1 Message Date
Ingo Bürk 7411dfa5ef
Merge pull request #3185 from orestisf1993/cmd_move_window_to_position
Remove 'method' from cmd_move_window_to_position
2018-03-21 08:38:41 +01:00
Orestis Floros 174dc389ff Remove 'method' from cmd_move_window_to_position
For command:
move window to [absolute] position X px Y px
if the optional keyword 'absolute' is provided the end result is the
same even though it is implemented differently. Only difference is that
with absolute the floating window can move completely outside of any
output.

This commit removes the 'method' argument and only keeps the sane
implementation.
2018-03-20 16:59:06 +02:00
Orestis Floros b467937808 Fix userguide link
[[move_to_outputs]] doesn't work currently:
https://i3wm.org/docs/userguide.html#move_to_outputs
This does:
https://i3wm.org/docs/userguide.html#_moving_containers_workspaces_to_randr_outputs

This combines a 'BlockId Element' with an 'anchor'. Both should work
now.
2018-03-19 18:30:22 +02:00
Klorax 9017a17e39
Docs [#3164]: Clarification about X resource value
Clarification about X resource value: they are loaded verbatim and must therefore be in the format that i3 uses.
Solves #3164.
2018-03-11 18:04:32 +01:00
hwangcc23 2269b2e795 Add strip_workspace_name
See the issue #3163 (https://github.com/i3/i3/issues/3163).

Add strip_workspace_name to strip off the workspace name.
2018-03-11 12:17:42 +08:00
Ingo Bürk 2cffb978f0
Merge pull request #3138 from clawoflight/default-border
[WIP] Add default_{,floating_}border
2018-02-19 07:03:03 +01:00
Ben Creasy 306a7e46d3
Remove hardcoded 2013 date
The front page and docs landing page emphasize documentation, but the user guide looks like it hasn't been updated since 2013. It seems from the history of the file that this number is misleading. Let me know if I'm missing anything.
2018-02-18 18:44:40 -08:00
Bennett Piater f8d6c10d7c
Add default_{,floating_}border to config
userguide: document default_{,floating_}border

201-config-parser.t: add new tokens to $expected_all_tokens

201-config-parser-t: fix whitespace

closes i3/i3#2702
2018-02-15 16:25:56 +01:00
livanh 7b59da8a4f Implement 'resize set <width> ppt <height> ppt' command for tiling windows (#3036) 2018-01-08 23:25:08 +01:00
clonejo eb679bfabd Docs: state that pango markup requires the use of a pango font. 2017-12-27 17:41:55 +01:00
Pallav Agarwal 161db6f17d Add relative coordinates in JSON for i3bar click events (fixes #2767)
Add support for relative coordinates in i3bar click events

Rename {x,y}_rel to relative_{x,y}

Update i3bar-protocol doc to mention the added fields in click events
2017-12-20 22:51:14 +05:30
Orestis Floros 994a479558 userguide: mention <criteria> in focus 2017-12-11 19:14:33 +02:00
Orestis Floros 315ff17563 Add '--release' flag for bindsym in the bar block
i3bar's handle_button is modified to also handle XCB_BUTTON_RELEASE
events. During these button release events, only custom commands are
checked to avoid sending multiple workspace ipc messages.

The way this patch is implemented will allow to assign a custom command
for both the press and release of the same button:
bar {
  ...
  bindsym buttonX exec command1
  bindsym --release buttonX exec command2
}

Fixes #3068.
2017-12-08 12:16:22 +02:00
Daniel Mueller 3a22c6e765
docs/userguide: Correct mark/goto i3-input commands
The userguide still mentions an old 'goto' command which no longer
exists and will be ignored silently (when used in the i3 config) or
causes an error to be reported (when invoked from the command line).
This change updates the userguide to correct this problem. In addition
to that it also updates the i3-input command shown to no longer use the
deprecated -p flag but -F instead.
2017-11-11 17:06:43 -08:00
Orestis Floros b17e7b82c6 Add support to resize floating container in percentage
resize set is modified to accept both 'px' and 'ppt' height and width.

Fixes #2816.
2017-10-18 02:07:11 +03:00
Michael Stapelberg 906a88e92b docs: full-size, so-called (#3019)
As per Michael Siegel, who studied the English language :).
2017-10-15 14:22:41 +02:00
Michael Stapelberg 4f03e49c3a userguide: explain why Mod4 is usually preferred (#3018) 2017-10-15 12:17:22 +02:00
Michael Stapelberg 44a6efb5b0 tests: run under Xvfb by default (if available) (#2951)
This shaves off two seconds of wall-clock time (10s → 8s).
2017-10-13 00:18:49 -07:00
Michael Stapelberg ce21de8dde Implement the tick event
This makes our tests less flaky, shorter, and more readable.

fixes #2988
2017-09-30 11:41:57 +02:00
Michael Stapelberg c08ef36199 docs/ipc: include new Go package, reference example byteorder code (#3000) 2017-09-29 14:02:18 -07:00
Michael Stapelberg 54d61b510d Merge pull request #2953 from CyberShadow/focus_wrapping
Add "focus_wrapping" option
2017-09-27 09:31:39 -07:00
Vladimir Panteleev 50edf495aa
Merge "force_focus_wrapping" option into "focus_wrapping force"
Allow enabling forced focus wrapping by specifying "focus_wrapping
force" in i3's configuration. This syntax supersedes the previous
"force_focus_wrapping yes" one, which remains available for backwards
compatibility.
2017-09-25 18:58:12 +00:00
Michael Stapelberg 362cbe6c5f docs/ipc: document the GET_CONFIG request (#2984)
This was neglected in commit a6d8ed9b1a

related to #2856
2017-09-24 17:25:41 +02:00
Michael Stapelberg d968d39b27 Replace http:// with https:// where applicable
The testcases will be updated automatically in a separate commit.
2017-09-24 10:19:07 +02:00
Vladimir Panteleev 28f7e14650
Add "focus_wrapping" option
Fixes #2352.
2017-09-22 23:40:41 +00:00
Ingo Bürk dd13cae5c0 Merge pull request #2959 from orestisf1993/issue-2764
Allow assign to output
2017-09-22 16:24:26 +02:00
Vladimir Panteleev 536f60e230
docs/userguide: Update description of focus wrapping
Focus wrapping applies to all kinds of containers, not just
tabbed/stacked ones.
2017-09-21 15:32:44 +00:00
Michael Stapelberg 8e5731bde8 ipc: document how to detect i3’s byte order in memory-safe languages (#2961)
related to issue #2958
2017-09-18 17:15:28 +02:00
Michael Stapelberg 39415fe16d docs/ipc: "urgent": complete the list of container types (#2967)
Thanks chressie!
2017-09-18 16:36:34 +02:00
Michael Stapelberg 607e97e651 ipc: rename COMMAND to RUN_COMMAND for consistency (#2956)
All other message types are verbs, only our first-ever message COMMAND wasn’t.

While we’re here, also change the message type dictionary into a table with
clickable links to the corresponding reply type.

Authors of downstream IPC libraries are encouraged to keep the old name around
so as to not break existing code, but mark it as deprecated.
2017-09-17 15:25:00 +02:00
Orestis Floros a35854ddf4 Allow assign to output
Implements the "assign" part of issue #2764.
2017-09-17 15:37:17 +03:00
Orestis Floros 45d1e51857 Fix userguide formatting error 2017-09-17 15:37:17 +03:00
Michael Stapelberg 5062dd61bc ipc: tree reply: document focus, nodes and floating_nodes (#2955)
These haven’t ever changed, but were only included in the example, not in the
list, so people might not have realized that these are safe for use.
2017-09-16 17:28:44 +02:00
Ingo Bürk 8cad1c1fa6 Merge pull request #2887 from orestisf1993/next
Allow assign to workspace by number
2017-09-15 21:26:35 +02:00
Orestis Floros eaf7a49e28 Allow assign to workspace by number
Makes "assign [<criteria>] workspace number <number>" work in the same
manner as "move to workspace number <number>" instead of assigning the
window to a workspace named "number <number>".

config.spec is modified to expect a 'number' string and an extra
argument is used in cfg_assign.

For workspaces that don't exist yet, workspace_get is used as a
fallback. This also allows the user to assign to "<number> <workspace>"
eg "2: work" and the full name will be used if workspace number 2
doesn't exist yet.

Fixes #2590.
2017-09-15 03:38:13 +03:00
Michael Stapelberg 44e4ad52f6 Merge pull request #2920 from CyberShadow/monitor-output-names
Consider RandR 1.5's monitors' output names in addition to monitor names
2017-09-13 10:58:38 +02:00
Vladimir Panteleev 3b75be1334
docs/userguide: Document that i3 can accept RandR output names 2017-09-13 08:23:27 +00:00
Michael Stapelberg 48fbb3e9ef testsuite: install Module::Install so that AnyEvent-I3/Makefile.PL works (#2940)
As per https://perlmaven.com/cant-locate-inc-module-install-in-inc, the inc/
directory should not be under version control.

fixes #2914
2017-09-12 22:16:36 +02:00
Orestis bcaec96414 Fix userguide bug (#2932)
Fixes #2931
2017-09-11 21:31:29 +02:00
Vladimir Panteleev 7116bbaa12
docs/hacking-howto: Update section topology
- Promote the "How to build?" sub-section to a top-level
  section ("Building i3")

- Convert the "Introduction" sub-section as the intro to the remaining
  contents of the "Using git / sending patches" section

- Keep "Which branch to use?" as a level-3 sub-section, thus making it
  a sub-section of what used to be the "Introduction" sub-section.
2017-09-11 13:16:44 +00:00
Vladimir Panteleev e799bda2da
docs/hacking-howto: Promote "How to build?" sub-section
Move the "How to build?" sub-section to the top of its parent section.
2017-09-11 13:16:34 +00:00
Vladimir Panteleev 5c693ec2ae
docs/hacking-howto: Promote "Using git / sending patches" section
Move the contents of the "Using git / sending patches" section to the
top of the document.
2017-09-11 13:04:58 +00:00
Vladimir Panteleev 828c759489 docs/testsuite: Correct Xephyr package name on Arch Linux (#2913)
The package is called `xorg-server-xephyr`, not `xorg-xserver-xephyr`.
2017-09-10 13:02:10 +02:00
Chih-Chyuan Hwang 044f03d5c7 Update doc for dependency Module::Install (#2877)
After moving to AnyEvent-I3, a new testsuite dependency is introduced: Module::Install.
Update the doc for this.
See the issue #2876.
2017-08-28 09:43:42 +02:00
Johannes Lange 1b0c9958d0 docs markup fixes 2017-08-26 11:22:34 +02:00
Trevor Merrifield a805676197 Document missing case of workspace event
The docs are missing the "move" workspace event emitted from
workspace.c's workspace_move_to_output function.
2017-07-30 01:14:07 -04:00
Trevor Merrifield 6a8a4266f3 Add missing newline to end of file 2017-07-30 00:59:53 -04:00
hwangcc23 e63070607f Add compilation instructions to the hacking howto 2017-06-03 23:21:42 +08:00
Armaël Guéneau b2ee718f56 Add a link to the ocaml-i3ipc library 2017-05-31 16:53:33 +02:00
hwangcc23 bbfdcfddfe Update testsuite docs
After moved to autotools, the method to run the i3 testsuite is changed.
Update the testsuite document to reflect the change.
2017-05-21 23:08:27 +08:00