When a named workspace (i.e., a workspace that has a name that does not
begin with text that can be parsed as an integer greater than or equal
to zero) is represented by the ipc as a workspace json object such as
can be queried with `i3-msg -t get_workspaces`, set the num property to
-1 instead of json null.
This is for convenience of ipc consumers using type-constrained
languages such as C which have difficulty cleanly expressing nullable
integers.
fixes#1368
Users can specify a command to run when a button was pressed on i3bar to
override the default behavior. Currently only the mouse wheel buttons
are supported. This is useful for disabling the scroll wheel action or
running scripts that implement custom behavior for these buttons.
Example:
bar {
wheel_up_cmd nop
wheel_down_cmd exec ~/.i3/scripts/custom_wheel_down
}
fixes#1104
A configured mouse binding (for example `bindsym button3 kill`) runs
its command when the mouse button is pressed over parts of a container.
If the binding has no modifer, it will only run when the button is
clicked on the window titlebar.
Otherwise if the binding has a modifier, it will run over the titlebar
or any part of the contained window.
fixes#558
In the section "Exiting i3", document the confirmation dialog (nagbar)
that will show when the user presses the default keys to exit in such a
way to hint that it is configurable.
This patch adds a new configuration option "mouse_warping [output|none]".
When mouse warping is disabled, mouse cursor does not jump to middle of current
screen when changing workspaces between multiple outputs. This introduces a
"special" cursor state, where focus is in one window and cursor on another.
Useful for eg. scrolling a web page with mouse wheel while typing into another
window on keyboard.
Implement the configuration option within the bar config directive for
custom workspace numbers with the directive `strip_workspace_numbers
yes`.
This directive strips the workspace name of the number prefix and
delimiter. When the workspace name consists only of the number, it will
default to show the number.
For example:
* "2:5" -> "5"
* "4:$" -> "$"
* "8" -> "8"
This allows customization of i3bar for alternate ordering of workspaces
which has a legitimate use for alternate keyboard layouts such as
Dvorak.
fixes#1131
The fullscreen_mode event is a window with the "change" property set to
"fullscreen_mode". This event should be emitted whenever a window enters
or exits fullscreen mode.
This event can be used to turn off dpms off when a window is fullscreen
or display the fullscreen container name in the status line for
instance.
Send all the options in the bar block on the barconfig_update event.
This will eventually allow for dynamically updating bar colors with the
`reload` command.
Add a link to the new JavaScript, Python, and Lua ipc libraries.
Add notice that the older Python libraries are not maintained.
Sort the list alphabetically.
This patch fixes ticket #1168 to extend the window IPC event mechanism
to send IPC events for window focus and title changes. The newly added
window events use the same format as the already established "new"
event.
Specifically this patch:
* Moves the ipc_send_window_event() function from src/manage.c into
src/ipc.c and adds an argument for the change property of the event
* Updates src/manage.c to use the new function signature. To ensure
that the "new" event does not send the same event data as the
"focus" event, setting focus now happens after the "new" event
has been sent
* Adds IPC focus event notification to src/x.c. To workaround a problem
during window close when accessing the window name, a function has been
added to query whether a window is actually attached to its parent. To
avoid obsolete focus notification, a new field has been added to keep
track of the focus without any interference by the click handling
* Adds IPC title event notification to src/handlers.c. To avoid
obsolete title notification, a function has been added to determine
whether a window title has actually changed
* Updates the IPC documentation to include the new events
* Updates testcases/t/205-ipc-windows.t to include the "focus" event
in order to ensure the correct event sequence
* Adds two new unit tests, b/testcases/t/219-ipc-window-focus.t and
b/testcases/t/220-ipc-window-title.t to ensure proper "focus" and
"title" events
Add a link to https://github.com/acrisci/i3-ipc which is a new ipc
library in the design phase of development. When it is stable, it will
provide bindings to many high-level scripting languages with
GObject-introspection.
This project aims to replace the unmaintained Python library and offer
an ipc library in new languages such as Lua and JavaScript.
The user's guide talks about renaming workspaces, for example to
"2: mail", and a sample key binding for use with i3-input is supplied.
However, this example lacks proper quoting for the format string, so
that when workspace name with a space in it, like "2: mail", is given,
the current workspace is renamed to "2:". This patch adds proper
quoting.
i3 current behavior hides the binding mode indicator when
workspace buttons are disabled.
This patch adds a new configuration for i3bar called
'binding_mode_indicator' which acts like the workspace_buttons.
It is now possible to configure i3bar to hide the
workspace buttons and keep showing the binding mode indicator.
This should make the hide workspace buttons configuration
more convenient for those who are heavily using binding
modes.
Default value for binding_mode_indicator is true.