Previously we created a new instance on every connected signal. We should
instead create the device once and then just re-start the sync process when
we get the connected data.
./tuhi/ble.py:14:1: F401 'sys' imported but unused
./tuhi/ble.py:15:1: F401 'enum.Enum' imported but unused
./tuhi/ble.py:16:1: F401 'gi.repository.GLib' imported but unused
./tuhi/ble.py:26:1: E302 expected 2 blank lines, found 1
./tuhi/ble.py:81:1: W293 blank line contains whitespace
./tuhi/ble.py:84:13: E126 continuation line over-indented for hanging indent
./tuhi/ble.py:85:17: E131 continuation line unaligned for hanging indent
./tuhi/ble.py:203:39: F821 undefined name 'WACOM_CHRC_LIVE_PEN_DATA_UUID'
./tuhi/ble.py:204:38: E128 continuation line under-indented for visual indent
./tuhi/ble.py:205:39: F821 undefined name 'WACOM_OFFLINE_CHRC_PEN_DATA_UUID'
./tuhi/ble.py:206:38: E128 continuation line under-indented for visual indent
./tuhi/ble.py:207:39: F821 undefined name 'NORDIC_UART_CHRC_RX_UUID'
./tuhi/ble.py:208:38: E128 continuation line under-indented for visual indent
./tuhi/ble.py:232:1: E302 expected 2 blank lines, found 1
./tuhi/ble.py:240:13: E126 continuation line over-indented for hanging indent
./tuhi/ble.py:241:17: E131 continuation line unaligned for hanging indent
./tuhi/ble.py:250:21: E126 continuation line over-indented for hanging indent
./tuhi/ble.py:263:43: W291 trailing whitespace
./tuhi/ble.py:272:72: W291 trailing whitespace
./tuhi/ble.py:310:1: W391 blank line at end of file
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
./tuhi/dbusserver.py:55:1: E302 expected 2 blank lines, found 1
./tuhi/dbusserver.py:75:17: E126 continuation line over-indented for hanging indent
./tuhi/dbusserver.py:77:29: E203 whitespace before ':'
./tuhi/dbusserver.py:155:13: E126 continuation line over-indented for hanging indent
./tuhi/dbusserver.py:156:17: E131 continuation line unaligned for hanging indent
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
tuhi/wacom.py:18:1: F401 'sys' imported but unused
tuhi/wacom.py:22:1: F401 'tuhi.dbusserver.TuhiDBusServer' imported but unused
tuhi/wacom.py:23:1: F401 'tuhi.ble.BlueZDeviceManager' imported but unused
tuhi/wacom.py:52:1: E302 expected 2 blank lines, found 1
tuhi/wacom.py:140:13: E126 continuation line over-indented for hanging indent
tuhi/wacom.py:141:17: E131 continuation line unaligned for hanging indent
tuhi/wacom.py:592:1: W391 blank line at end of file
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
It didn't make quite sense to have y before x, and with some inverted
x value. The sensors are designed in the landscape mode, and the rotation
needs to be determined in the software.
Implement an orientation parameter to WacomDevice so we always have
normal X and Y
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
It's better to have a full log on one line. However, flake8 now complains.
I am not that happy with this situation, we should figure out a way
to selectively disable the length check for logger messages only.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
bus_own_name is asynchronous, so we first need to send a signal back and then
we can start connecting to the devices. Otherwise we'll have to implement a
queue which would be a lot harder than just waiting.