Commit Graph

413 Commits

Author SHA1 Message Date
Benjamin Tissoires 013de2a6e4 wacom/live: do not fetch the width and height, rely on stored values
It's not like we are handling hundreds of devices. And this allows us to
be more flexible in which fields are replaced in the report descriptor.
2018-02-16 10:47:19 +01:00
Benjamin Tissoires cf4d5b184e wacom/live: make the pressure dependent of the class
The Intuos Pro has 4096 levels of pressure, while the Slate and the Spark
only has 2048. We should do something about it.
2018-02-16 10:47:19 +01:00
Benjamin Tissoires 18221dfd58 wacom/live: fix physical maximums
This way, udevadm shows on the Slate:
E: ID_INPUT_HEIGHT_MM=148
E: ID_INPUT_TABLET=1
E: ID_INPUT_WIDTH_MM=216

Fixes #84
2018-02-16 10:47:19 +01:00
Benjamin Tissoires ee15b474fd wacom/live: make sure the kernel assigns INPUT_PROP_POINTER
The wacom kernel driver assigns INPUT_PROP_DIRECT if we use the
application Pen. Using the Digitizer one fixes that.
2018-02-16 10:47:19 +01:00
Peter Hutterer 7b246e0892 wacom: add packet handling of the two initial packets the IntuosPro sends
One is a fixed header, one  is the stroke timestamp
2018-02-16 15:43:28 +10:00
Peter Hutterer 31ab5f37d3 wacom: move stroke prefix handling into a packet handler 2018-02-16 15:43:28 +10:00
Peter Hutterer 5692a1f3b2 wacom: add PacketHandlers for handling special commands
For data packets other than basic motion/pressure strokes, add a PacketHandler
that can deal with that particular packet. Those handlers are part of the
class declaration, when we instantiate a protocol we pull them all into a
packet_handlers list and go through them. The first one to return True is
considered the right handler and we expect something has been done with the
packet.

This patch includes the handlers for the end-of-stroke and end-of-sequence
packets, the rest to be added later.
2018-02-16 15:43:28 +10:00
Peter Hutterer 43064b58fc wacom: add a WacomPacket class
Instad of carrying around a lot of parameters, move this into a class with
properties. Eventually we can subclass that one for the special opcodes (or
something...)
2018-02-16 15:43:28 +10:00
Peter Hutterer 23e18cea67 drawing: add a stroke.seal() functionality
Makes end-of-stroke handling easier, we can call seal() on the current stroke
and it'll make drawing.current_stroke() None, which is something we can deal
with.
2018-02-16 15:43:28 +10:00
Peter Hutterer 155a11104c wacom: print an error if our device is more than 5 mins out 2018-02-16 15:43:28 +10:00
Peter Hutterer 09bfe44dd7 drawing: rename the stroke from 'l' to 's'
Leftover copy/paste error from when this class had a Layer subclass
2018-02-16 15:43:28 +10:00
Peter Hutterer 9fbfe17e13 ble: disable a debug message
Now that we got the basics running and reliable, this debug message is mostly
just noise, especially when in an office with lots of bluetooth devices
around. Comment it out, to be enabled when necessary.
2018-02-16 15:43:28 +10:00
Benjamin Tissoires 17dc80bea3 wacom: fix report descriptor logical min/max
Changing the python representation is not enough. We also need to change
the HID marker with the correct size.

Fixes 67b4d2b8fe
2018-02-14 13:11:37 +01:00
Peter Hutterer d0001e18ed tools: chmod +x on tuhi-live 2018-02-14 16:25:56 +10:00
Peter Hutterer a5c9d12a18 README: document live mode
Fixes #89
2018-02-14 16:13:29 +10:00
Peter Hutterer 67b4d2b8fe wacom: allow 4 bytes for width/height
Intuos Paper needs more than 16 bits

Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
2018-02-14 15:52:34 +10:00
Peter Hutterer 138497a73b wacom: add support for the Intuos Pro 2 paper 2018-02-14 15:03:02 +10:00
Peter Hutterer 7796d3c110 wacom: don't add points to the log until we have an absolute value
On the Intuos Pro at least we sometimes get events that are all relative at
first and it can take several events for us to have all three values as
absolute. This is likely a parsing error on our side, but meanwhile don't
write the data until we have at least one known value for all three axes.

And because the SVG writer isn't happy with empty strokes, add a seal()
function to the drawing to purge empty strokes.

Fixed #92 or at least works around it
2018-02-14 14:54:17 +10:00
Peter Hutterer 6c156efc01 wacom: make relative/abs events more obvious in the log
Mark the deltas with a * if they're the ones that changed.
2018-02-14 14:50:49 +10:00
Peter Hutterer 80d0066cef wacom: we only have one drawing per exchange
skip putting a single drawing in a list
2018-02-14 14:50:49 +10:00
Peter Hutterer c39b735e1e wacom: factor out the 'next stroke data' parsing 2018-02-14 14:50:49 +10:00
Peter Hutterer 8ecc397303 wacom: skip over the prefix when handling pen data
The prefix (4 bytes on the spark/slate) is some data that we don't know yet.
It *could* be the size of a tablet/drawing in LE byte order: 14434x29794
although that doesn't quite match the Intuos Pro data where the prefix is
different.

Either way, having this be an opcode of 0x3800 was probably just coincidence.
Let's skip over the header normally and assume that once we have a prefix, we
have a drawing. This opcode never occurs a second time within the same
drawing.
2018-02-14 14:50:49 +10:00
Peter Hutterer 876f35f806 wacom: factor out the prefix handling
The Intuos Pro has a different prefix, we'll need to override this. Dropping
the comment about the 8bt, on the intuos pro the prefix is nonsensical so
let's not leave a false lead there.
2018-02-14 14:50:45 +10:00
Peter Hutterer 726362107b wacom: append multiple nordic answers to each other
On the Spark, the 0xc9 CRC comes almost immediately after the 0xc8
end-of-sequence. This causes a race condition where sometimes we process the
0xc8 before the 0xc9 arrives, other times the 0xc9 overwrites the current
nordic_answer value before we get to it - triggering an unexpected opcode
exception.

Fix this by appending the nordic answer and only ever pulling off enough to
satisfy the current request.

Fixes #90
2018-02-14 11:25:13 +10:00
Peter Hutterer 240b982070 wacom: fix Spark CRC check
All it needs is less reversing
2018-02-14 11:25:13 +10:00
Peter Hutterer 45d4d6fb9b wacom: merge two debug strings 2018-02-14 09:45:49 +10:00
Benjamin Tissoires 422045e2fd wacom: insert proper ranges for X and Y in the uhid device
Also fix the pressure range to be 2047
2018-02-14 06:23:25 +10:00
Benjamin Tissoires 99a2f7bdc5 kete: parse incoming uhid data 2018-02-14 06:23:25 +10:00
Benjamin Tissoires d295e12310 wacom: create a uhid device on live mode
uhid code taken from https://github.com/bentiss/hid-tools and stripped out
from the not required parts here
2018-02-14 06:23:25 +10:00
Benjamin Tissoires d4dd672b2f live-mode: properly pack the fds over DBus
Keeping this one as a separate commit, so we can use it as a future
reference.
2018-02-14 06:23:25 +10:00
Benjamin Tissoires fec265cb68 live: add a script to run as root that enable live mode
we want to be able to open uhid, so we need root access.
Root access is bad, so we fork the process, and then immediately drop
the privileges to talk to the dbus dameon (or to create one).
2018-02-14 06:23:25 +10:00
Benjamin Tissoires 3eca8da251 kete: add live debugging mode
Just start/stop live mode, the debug happens in the tuhi process.

That's enough until we figure out the DBus API if we need one
2018-02-14 06:23:25 +10:00
Benjamin Tissoires 1a6d0205df tuhi: hook up live mode
Currently just enable/disable live mode.
The int parameter is doomed to be an opened fd to the uhid node
2018-02-14 06:23:25 +10:00
Benjamin Tissoires 41a3c85b59 kete: export the connected state of the bluez device to the tuhiketedevice
We need this in the live mode as the connection will be longer than
the usual retrieval of the data.
2018-02-14 06:23:25 +10:00
Benjamin Tissoires e4e0a3b8aa kete: rename the script from tuhi-kete.py to kete.py
Python doesn't really like minus signs in file names, especially
when you start importing the modules. Rename kete from tuhi-kete.py
to kete.py so it makes it easier to have other scripts in the tools
folder to borrow code from kete.
2018-02-14 06:23:25 +10:00
Peter Hutterer 7ff760dcbf wacom: add support for a set_name on the Spark
Part of #82
2018-02-13 15:23:05 +01:00
Benjamin Tissoires 590de68269 kete: make Searcher and Listener symmetrical regarding logs
The 'searching' notification was only emitted when it goes to stop, which
means we do not get notifications when it starts.
This makes SearchStopped signal redundant for the generic case, but allows
to get notifications if the search failed to start.

Rest is just making sure we have the same handling of events in Listener
and Searcher.
2018-02-13 14:51:40 +01:00
Benjamin Tissoires d8808e144f kete: better handling of clean up of connection/disconnection of signals
If stop() is called more than once, we might try to disconnect the
signals more than once, which raises some errors.
Better having one central place that handles the disconnect properly.
2018-02-13 14:51:40 +01:00
Peter Hutterer 30620dfbf0 tuhi: when a device toggles 'registered', send out the required signal
Related to #80
2018-02-13 14:51:40 +01:00
Peter Hutterer 58220efe31 kete: don't assume all devices are unregistered when searching
Instead, wait for the signal from tuhi and then go for it.

Fixes #80
2018-02-13 14:51:40 +01:00
Peter Hutterer ad0e81b395 base: push the mode down to the TuhiDevice
A device isn't registered or not, it's merely in a *state* of being
registering or not. Pass the current mode down to the TuhiDevice instead of a
boolean for 'registered'. The 'registered' gobject property is left in-place
for now, the dbus server needs it.
2018-02-13 14:51:40 +01:00
Peter Hutterer 720955db7c tuhi: try to register even if the device is not in register mode
Let's throw an exception when trying to connect.
2018-02-13 14:51:40 +01:00
Peter Hutterer 393056d5e8 base: remove another register_mode in favour of DeviceMode 2018-02-13 14:51:40 +01:00
Peter Hutterer 637f539194 ble: drop the 'event' argument from device-added
An 'event' boolean is less than obvious ('is-event' may be better). This
signalled the difference between a device-added during Manager startup and the
device-added at runtime (i.e. device goes online).

We don't need that differentiation. The manager adds all existing devices
immediately after connnect_to_bluez(). All we have to do is run through the
device list, add them locally and then subscribe to the signal.

This keeps the is-event confusion within one file only instead of spreading it
across two and an internal API. And we can re-name it to hotplugged.
2018-02-13 14:51:40 +01:00
Peter Hutterer 2ff4f8bca6 base: make the register/listen call handling more literal
Calling listen on an unregistered device currently triggers a register on the
device. This can happen when the device has been registered but the
ManufacturerData has not yet been updated.

Disentangle this by only calling the right function based on what we're trying
to get. This also requires that the connected/disconnected signals are only
handled when we're actually trying to do something with them.

Fixes #79 (multiple patches required)
2018-02-13 14:51:40 +01:00
Peter Hutterer 4661cf9ae8 wacom: remove state-based decision of whether to listen or register
Previously, we set self._mode and used that to determine what connection to
attempt. This can sometimes lead to a device attempting to register in
response to a listen() request (and vice versa).

Make this dependent on the caller arguments only. So when listen() is
requested do exactly that and generate the right exception if the device is in
the wrong mode.

Fixes #79 (multiple patches required)
2018-02-13 14:51:40 +01:00
Peter Hutterer 0d825e2e3c wacom: replace the signal forwarders with lambdas
We're doing nothing but forwarding the signal here, so let's just replace them
with lambdas so it's immediately obvious what we do with the signal.
2018-02-13 14:51:32 +01:00
Peter Hutterer 94bc52efb6 kete: if listening/searching is stopped by the daemon, clean up after us 2018-02-13 14:49:39 +01:00
Benjamin Tissoires abfb0db6a8 kete: catch the ServiceUnknown exception in TuhiKeteDevice
This allows to have more symmetrical handling of the Searcher and
the Listener
2018-02-13 14:49:17 +01:00
Peter Hutterer de033c3b6a wacom: 0x05 appears to be the error for 'invalid opcode' 2018-02-12 15:30:16 +10:00