tuhi/drawing.py:46: PyGIDeprecationWarning: GObject.property is deprecated;
use GObject.Property instead
@GObject.property
Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
No need to get triggered by BlueZDeviceManager when it finds any GATT
characteristic. The BlueZDevice just needs its 'ServicesResolved' and
can resolve the GATT characteristics itself.
This solves a FIXME.
Signed-off-by: Daniel Martin <consume.noise@gmail.com>
The object list returned by object managers get_objects() function is
not sorted. Though, we rely on objects being sorted by their object
path.
Replace the object managers get_objects() function with a variant
fixing that. Additionally, our variant makes it possible to filter
the returned object list by object path and interface.
Examples:
- get_objects():
/
/org/bluez
/org/bluez/hci0
/org/bluez/hci0/dev_00_00_00_00_00_00
/org/bluez/hci0/dev_00_00_00_00_00_00/service0000
/org/bluez/hci0/dev_00_00_00_00_00_00/service0000/char0000
/org/bluez/hci0/dev_00_00_00_00_00_00/service1111
/org/bluez/hci0/dev_00_00_00_00_00_00/service1111/char1111
/org/bluez/hci0/dev_FF_FF_FF_FF_FF_FF
/org/bluez/hci0/dev_FF_FF_FF_FF_FF_FF/serviceffff
/org/bluez/hci0/dev_FF_FF_FF_FF_FF_FF/serviceffff/charffff
- get_objects(interface='org.bluez.Adapter1'):
/org/bluez/hci0
- get_objects(interface='org.bluez.GattCharacteristic1'
base_path='/org/bluez/hci0/dev_00_00_00_00_00_00'):
/org/bluez/hci0/dev_00_00_00_00_00_00/service0000/char0000
/org/bluez/hci0/dev_00_00_00_00_00_00/service1111/char1111
Signed-off-by: Daniel Martin <consume.noise@gmail.com>
b3 01 00 seems to be a generic "I'm happy" and the few others we've seen
are errors. So let's encode that and reconsider if it turns out to be false.
Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
we already are keeping a record of the x,y and p. So we are trying
to duplicate the effort by using new_rel.
The problem is that some reports have relative coordinates but absolute
pressure data. Which means we are missing the pressure change as it has
a relative value of 0.
By trusting the wacom internal state, we can have the json data that
matches it completely.
We need python 3.6 but old Ubuntus only have 3.5. 3.6 can be installed (and
thus we get past the 3.6 sys.version check), but the gi.repository backports
are in various states of disarray (see #103 and #104).
And Python (and in particular gi) makes it hard for users to distinguish
between "the dependencies are a mess" and "this is a bug in tuhi".
So let's catch any error during gi.repository import and print a warning to
the user, in the hope of getting less bugs caused by Ubuntu frankenpythons.
Still won't fix issues like #104, but I'm not sure how to test for those
errors.
Related to #103
Export the supported versions in a Manager property and require the client to
request a specific version in GetJSONData. Without that, the server could
never update the format and clients would have to support every single
historical version to make sure they can run against any version server.
Fixes#98
Because we're totally going to ship tuhi in embedded devices that are going to
be in use until after 2038 when time resets to zero, the world goes big bang
and the only survivers will be 64-bit species. Or something like that. Either
way, the API documentation already said so anyway and the DrawingsAvailable
property is already 64 bit too.
Semi-confusingly: the dbus 64 bit unsigned type is 't', it doesn't stand for
'timestamp'.
It can easily take more than 5 seconds when reading the data. The current
timeout just cuts the connection while it is still reading.
We *could* just remove the timeout here as the device will gracefully
send us a 0xc8 opcode with a blank CRC if we shut the device down while
retrieving the data.
However, better being on the safe side and keep a timeout, but restart it
if we are still getting pen data during the timeout.
Fixes#91
When using the live mode on the Slate, the bloc note actually hampers
the pen and prevents it to address all of the pixels on the screen.
Add some artificial boundaries that roughly match the primary design
of the device.
The Intuos Pro has a clip where you put a regular sheet of paper, so there
is no point restraining the active surface.
Fixes#88
For data packets other than basic motion/pressure strokes, add a PacketHandler
that can deal with that particular packet. Those handlers are part of the
class declaration, when we instantiate a protocol we pull them all into a
packet_handlers list and go through them. The first one to return True is
considered the right handler and we expect something has been done with the
packet.
This patch includes the handlers for the end-of-stroke and end-of-sequence
packets, the rest to be added later.
Instad of carrying around a lot of parameters, move this into a class with
properties. Eventually we can subclass that one for the special opcodes (or
something...)
Makes end-of-stroke handling easier, we can call seal() on the current stroke
and it'll make drawing.current_stroke() None, which is something we can deal
with.
Now that we got the basics running and reliable, this debug message is mostly
just noise, especially when in an office with lots of bluetooth devices
around. Comment it out, to be enabled when necessary.
On the Intuos Pro at least we sometimes get events that are all relative at
first and it can take several events for us to have all three values as
absolute. This is likely a parsing error on our side, but meanwhile don't
write the data until we have at least one known value for all three axes.
And because the SVG writer isn't happy with empty strokes, add a seal()
function to the drawing to purge empty strokes.
Fixed#92 or at least works around it
The prefix (4 bytes on the spark/slate) is some data that we don't know yet.
It *could* be the size of a tablet/drawing in LE byte order: 14434x29794
although that doesn't quite match the Intuos Pro data where the prefix is
different.
Either way, having this be an opcode of 0x3800 was probably just coincidence.
Let's skip over the header normally and assume that once we have a prefix, we
have a drawing. This opcode never occurs a second time within the same
drawing.
The Intuos Pro has a different prefix, we'll need to override this. Dropping
the comment about the 8bt, on the intuos pro the prefix is nonsensical so
let's not leave a false lead there.
On the Spark, the 0xc9 CRC comes almost immediately after the 0xc8
end-of-sequence. This causes a race condition where sometimes we process the
0xc8 before the 0xc9 arrives, other times the 0xc9 overwrites the current
nordic_answer value before we get to it - triggering an unexpected opcode
exception.
Fix this by appending the nordic answer and only ever pulling off enough to
satisfy the current request.
Fixes#90
A device isn't registered or not, it's merely in a *state* of being
registering or not. Pass the current mode down to the TuhiDevice instead of a
boolean for 'registered'. The 'registered' gobject property is left in-place
for now, the dbus server needs it.
An 'event' boolean is less than obvious ('is-event' may be better). This
signalled the difference between a device-added during Manager startup and the
device-added at runtime (i.e. device goes online).
We don't need that differentiation. The manager adds all existing devices
immediately after connnect_to_bluez(). All we have to do is run through the
device list, add them locally and then subscribe to the signal.
This keeps the is-event confusion within one file only instead of spreading it
across two and an internal API. And we can re-name it to hotplugged.
Calling listen on an unregistered device currently triggers a register on the
device. This can happen when the device has been registered but the
ManufacturerData has not yet been updated.
Disentangle this by only calling the right function based on what we're trying
to get. This also requires that the connected/disconnected signals are only
handled when we're actually trying to do something with them.
Fixes#79 (multiple patches required)
Previously, we set self._mode and used that to determine what connection to
attempt. This can sometimes lead to a device attempting to register in
response to a listen() request (and vice versa).
Make this dependent on the caller arguments only. So when listen() is
requested do exactly that and generate the right exception if the device is in
the wrong mode.
Fixes#79 (multiple patches required)
We only ever used it in conjunction with vendor_id, so we can just make this a
normal property and send GObject notifies when it changes. This allows us to
listen for the MD to change when it finished registration.
[BT: do not add the second indirection by calling vendor_id]
Fold register_connection into register_device and (with comments) handle the
spark and slate here. This makes it easier to handle the Intuos Pro paper
later.
During the first attempt to register, we might not know before hand
the protocol of the device. Have a special class for it, and then
instantiate the correct protocol before continuing.
This makes the 'Protocol' entry in the config file mandatory
The Slate is more recent than the Spark. We better have the Spark as a
base class that we will never touch again and make the Slate depend on it.
When adding the Intuos Paper, we should make it a subclass of the Slate,
as the 2 protocols are similar.
The Intuos Pro Paper is close enough to the Slate but with some
subtleties. Instead of having a bunch of ifs, let's have nice subclasses
for the differences in the protocol.
We are already handling 2 protocols, one for the Spark, and one for
the Slate. That's one too many, and given that there are some subtleties
in the Intuos Pro Paper (see #56), we better start splitting the protocol
from the interface, so we can have different protocols for different
devices instead of having a bunch of 'ifs'
The Intuos Paper uses a different one, because of course it does.
The 'company ID' from the Paper will be added while adding support for it.
Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
This isn't something we need in the daemon, it depends too much on what the
client expects so let the client save this data and handle the rotation
accordingly.
Note that the sensor in Sparks and Slates is in landscape format, i.e. every
picture is 90 deg rotated from what you'd expect.
Fixes#33 (wontfix)
Instead of failing with a syntax error on format strings, actually bail out
instead. Likewise for setup.py, require 3.6 and add this to the classifiers
too while we're there.
Related to #71
"pair" is alrady taken by Bluetooth and since we have a bluetooth device here,
it can cause confusion. Use "register" instead, with an explanation in the
README for the more paranoid of us.
Fixes#67
While running the app in flatpak, there are a few deprecation warnings
coming in:
PyGIDeprecationWarning: GObject.SIGNAL_RUN_FIRST is deprecated;
use GObject.SignalFlags.RUN_FIRST instead
PyGIDeprecationWarning: GObject.property is deprecated;
use GObject.Property instead
PyGIDeprecationWarning: GObject.MainLoop is deprecated;
use GLib.MainLoop instead
If a client requested both listen and search, on listen off on the device,
the discovery was stopped too which lead to some unbalanced state in
the client.
Tuhi is not a permanent storage for drawings, this needs to be handled by the
client(s). To make sure no-one is tempted to use it as permanent storage,
always delete all but the last 10 drawings on startup.
Fixes#45
Spark is the past, Slate is the future.
Spark seems to have its own protocol, while the Slate and the Folio are
supposed to have the same firmware. We should probably make Spark the
exception than the other way around.
Relying on the name is a bad idea because:
- the Wacom Inkspace app asks the user to change the name of the device
on pairing
- the FW should be slightly the same between generations (Folio and Slate
vs Intuos Pro Paper edition vs Spark)
It appears the Spark doesn't have the "Mysterious characteristics"
mentioned here. And this characteristics seems to send a wacom-like
protocol when pairing to the device or from time to time.
Attempt to differentiate between the Spark and the rest based on that
so we can hope to support the Folio too, and maybe the Intuos Pro Paper
Edition.
Let's the developers of tuhi to consume more energy in their monitor
to light up more pixel when displaying single quotes whereas double
quotes.
It also makes the whole bit more uniform.
Fixes#32
And let us handle the local time zone conversions in the client, because
having timestamps in localtime in the daemon is confusing and error-prone (how
is the client supposed to know what localtime was?)
fix ca82af78de ("tuhi: handle cold-plugged devices").
The point of deciding whether a device was in the pairing mode was actually
ignored when building the list of available devices.