This reverts commit e71c304444.
It turns out that several users have workflows in which they turn off
their monitors without using e.g. `xrandr --output DP-1 --off`. The
result is that the monitors are disconnected, but not disabled.
With commit e71c304444, i3 started to see
these two states as one and the same state, but that causes more harm
than it does good. For example, for some users with only one monitor, i3
would just exit when these users turned off their monitor.
related to #1858, #1839fixes#1845
With commit c738b2e454 we changed i3 so
that the default keybindings can be used when ISO_Next_Group is enabled,
but bindings which explicitly use Mode_switch have precedence. This
behavior required the use of bindcode instead of bindsym.
With this commit, when switching from group 1 to group 2 using
ISO_Next_Group, i3 will re-translate all keybindings (looking at column
2/3, regardless of whether the keybinding itself specifies Mode_switch)
and re-grab them.
That way, the keybinding “bindsym $mod+x nop foo” will work when
pressing $mod+x without Mode_switch and when pressing the corresponding
$mod+x (different key) with Mode_switch. A binding such as “bindsym
Mode_switch+$mod+x nop bar” will still have precedence.
The intention here is to make bindsym keybindings work well with dual
keyboard layouts (such as {dvorak, us} or {us, ru}), so that users can
switch between groups and still have their (logical) keybindings behave
the same way.
fixes#1775
Do not log an XCB_MOTION_NOTIFY event in handlers.c because this
clutters the log.
Only log in the motion notify handler if something important happens.
* common.mk: use -lsocket -liconv -lgen on Illumos/Solaris
* mkdirp: return int and accept a mode argument
* use i3's mkdirp on everything except Illumos
1. Allow to use the line continuation, which is indicated by \ before the new line character, in config files.
2. Add a new testcase "247-config-line-continuation.t" for
a). testing line continuation
b). making sure string escaping still works
c). testing line continuations within a string
b). testing line continuations with too many lines
If the match expression is a plain number (e.g., '99'), the number of a workspace will be compared strictly. Otherwise, the match expression is taken as a regular expression and compared against the workspace's name.
This allows all of the following:
for_window [workspace=5] ...
for_window [workspace="5:foo"] ...
for_window [workspace="foo"] ...
fixes#1769
Fix TODO in bindings.c.
There is no problem to use atoi here since either keycode 0 or button0 is invalid.
But strtol is more flexible and is recommanded for conversion.
The format string set with "title_format" can contain the placeholder "%title" which will be replaced with the actual window title.
By not overwriting window->name itself, we make sure that assignment matching still works as expected.
fixes#1723
Try to detect base 16 numbers given to `con_id` and `id` for command criteria
by setting the base of strtol to 0. This should also detect octal.
This is necessary because mouse bindings now may be serialized as hex as of
5c32de4.