When moving a workspace to the current output by way of a rename, if the
current workspace is empty, it will be removed by `workspace_show`.
Attempting to restore focus to this removed workspace causes a crash.
Follow the pattern in workspace.c:996 to only restore the original focus if the
original workspace still exists.
Add a test to ensure that the renamed workspace moves to its appropriate
output and that a crash does not occur.
Fixes#3228
When we don't modify the focus we aren't risking giving focus to a
container behind the current fullscreen one.
_con_move_to_con can with ignore_focus is called through the swap
command or through con_move_to_workspace for floating containers. This
change shouldn't break the expectations of the callers there.
Fixes issue #3259.
This is enough to fix the crash discussed in #3259 even though the next
commit can fix it independently. This commit is useful because it
generally makes sense to abort the command when the first call to
_con_move_to_con fails.
- 'border toggle' now accepts an optional pixel argument which will be
ignored when switching to BS_NONE.
- 'border pixel' now defaults to 1 pixel instead of 2.
- Calling 'border normal' or 'border pixel' will use the configured
default_border_width if one exists. Also applies to floating windows.
Fix the issue #3227(https://github.com/i3/i3/issues/3227).
1).Make cmd_scratchpad_show() use the information coming from scratchpad_show().
2).Add a test case 298-scratchpad-show.t.
Was used for the removed option 'terminal' and for 'font'. 'font' is no
longer this aggressive and doesn't use the macro.
Killing i3 when an option is missing would be super backwards
incompatible so I doubt we are going to use this ever again.
When i3bar is called with the -V flag but there is no 'verbose yes'
directive in the bar {} config, the verbosity config value is reset.
This will introduce the opposite, negligible issue: you can't disable
i3bar's verbosity by deleting the 'verbose yes' directive in the bar {}
config. To fix this we would need an enum for config.verbose.
Closes#3220.
The title marker lines have to be aligned with the previous lines.
The error was caught by asciidoctor, which tends to be picker than
asciidoc.
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Was a small typo.
This also has the (positive) side-effect of allowing to move all the
content of a marked workspace next to the target container, see added
tests.
Currently when renaming outputs, an output assignment of "left" will
cause the workspace to move left. Treat this assignment as a proper name
instead (even though it is unlikely an output will be named "left").
Move logic for determining output to move to out of
`workspace_move_to_output`
Add test for ignoring direcionality during rename.
Fixes#3208.
Using 'default:' cases can hide logical errors which would lead to i3
crashes for users. With this change the compiler will print a warning
when a case is not handled. For example, if I add a new value in the
Font.type enum:
../../i3/libi3/font.c: In function ‘draw_text’:
../../i3/libi3/font.c:378:5: warning: enumeration value ‘NEWFONT’ not handled in switch [-Wswitch]
switch (savedFont->type) {
^~~~~~
The current behaviour is buggy in the following layout:
T [ A* V [ B C ] ], where the focus stack in V is B > C.
When the user scrolls down, focus correctly moves to B but if the user
scrolls down again the whole vertical container is focused.
This happens because 'bool scroll_next_possible' is false but
con_activate is called on the tabbed container's sibling - the vertical
container.
i3bar’s X11 output is not what our testcases are testing — the state
manipulations which i3bar triggers via IPC messages to i3 are what we are
interested in.
Sending the sync command via IPC ensures pending IPC messages are handled by i3
before the sync response is read. This is rarely useful for direct IPC
connections to i3, but becomes useful when synchronizing with i3bar, which might
have pending IPC messages in response to button clicks.
Explanation for the changed test:
After $third is switched to floating, the test moves focus to $second.
So, the parent of $second (the stacked container) is above $third in the
focus stack and it's children ($first, $second) should get focused
before $second. When $second is switched to floating the correct focus
order for the workspace should be $second->parent (floating con is the
parent) > $first->parent (stacked con) > $third.
Fixes#1975