fake_outputs_init used a sprintf invocation with a throw-away buffer
to estimate how many characters the sscanf invocation consumed. This
was unnecessary, and also potentially incorrect, as differences
between the read and formatted strings (such as leading zeros) could
lead to fake_outputs_init to lose its track.
Instead, use the %n format specifier which allows saving the number of
characters consumed by sscanf so far. %n is part of C99.
I previously tried to fix the check, but could only come up with a fix which
required removing our module pre-loading, which makes the tests considerably
more expensive. Instead, let’s just remove the check.
$config is never touched after being initially set up.
Not restarting i3 between each test case reduces the runtime of this test by an
order of magnitude.
All other message types are verbs, only our first-ever message COMMAND wasn’t.
While we’re here, also change the message type dictionary into a table with
clickable links to the corresponding reply type.
Authors of downstream IPC libraries are encouraged to keep the old name around
so as to not break existing code, but mark it as deprecated.
This fixes a regression introduced in commit
4e88c10564ca5366c2578908f62ec56625a26718: when attempting to move the
single child of a container in the direction of another output, i3
would move the window to the output, despite the window not being at
the edge of its output, instead of moving it to its parent container.
The bug occurred because the check for moving containers across
outputs with non-default workspace layouts (issue #1603) did not
actually verify that the moved window lies at the edge of the
workspace, despite what its comment said.
Fixes issue #2466.
This commit also introduces slurp() which reads a file in its entirety. Using
this function instead of doing IO in the functions in load_layout.c again and
again makes the code cleaner (fixing at least two memory leaks) and avoids
re-reading the same file 3 times.
related to #2755
Convert the output names specified in the "output" and "tray_output"
fields in bar blocks in i3's configuration to the referred output's
primary name. This allows specifying names other than the primary
output's name in the given fields without changing the IPC protocol.
In addition to the name of the monitor itself (which is still used as
the i3 output's primary name), register RandR output names associated
with the RandR monitor as alternative i3 output names.
Currently, only one name is ever added, and only the first name is
ever accessed; actually using the capability to store and access
multiple names comes in the following commits.
Currently simply returns output->name, but this will make it easier to
change how output names are stored in the following commits.
Also replace reading output->name with invocations of
output_primary_name. Code which writes output->name is unchanged. Done
using a mostly mechanical replacement of output->name to
output_primary_name(output).
- Promote the "How to build?" sub-section to a top-level
section ("Building i3")
- Convert the "Introduction" sub-section as the intro to the remaining
contents of the "Using git / sending patches" section
- Keep "Which branch to use?" as a level-3 sub-section, thus making it
a sub-section of what used to be the "Introduction" sub-section.
The test runs `xrandr setmonitor`, which will otherwise affect any test
scheduled after 533-randr15.t, causing flakyness in t/217-NET_CURRENT_DESKTOP.t
for example.