- manage_window: log the window in the start of the function so that the
reader knows what the rest of the messages refer to, even if the
function exits prematurely.
- con_is_floating: Message is spammy
c2a1b6e9 was a bit overzealous, other actions should be executed if the
button was pressed after the workspace buttons but before the
statusline.
Also, should we allow other actions everywhere in the bar if click
events are disabled by the child?
- Having both parse_configuration and parse_file is excessive now
- We detect if we are parsing only by checking if conn is NULL, not with
use_nagbar
- font.pattern needs to be set to NULL because it is freed in
free_font()
Fixes#3660
Also fixes an issue where action would be called if the button press was
on a separator. For example, if a user scrolled on a separator, the
workspace would change.
Applies to --release commands as well.
Closes#3635.
Probably the bug can still happen when a tree_close_internal happens
inside a workspace_show but modifying the code to avoid them seems to
not be worth it.
- The result from con_get_output was always not NULL because
con_get_output asserts so
- get_output_by_name should always be able to get an output from the
corresponding container
- workspace_move_to_output doesn't return bool anymore since it can't
fail
This is a regression from bce088679.
An other way to fix this would be to concatenate strings inside the
strtok loop when an output starts with a double quote but I'd rather
let the parser do the word splitting.
Fixes#3646
This fixes a crash which I could not reproduce in a testcase with reasonable effort, but the user reported the fix works.
Compare with src/x.c:946.
fixes#3554fixes#3645
Fixes#3595
Like the issue mentions:
> instead of the newly created workspace (not referenced by variable
> here) the `"init"` event is fired with the current workspace (`ws`).
Plus, there was another issue where duplicate workspace init events
where being sent because of workspace_get().
304-ipc-workspace-init.t: Subtest "move workspace to output" fails with
current next.
Fixes#3631
No event was being sent here:
2d6e09a66a/src/randr.c (L487)
533-randr15.t: I confirmed that SKIP still works if the xrandr command
fails.
Added test fails with current next.
- __lsan_do_leak_check() will terminate the process, so move it to the
end of the function.
- ev_loop_destroy() must be called after ipc_shutdown() because the
latter calls ev_ functions.
Fixes#3599
I was able to reproduce #3579 in Linux by running:
`sudo sysctl net.core.wmem_default=10000`
If a subscription message was too big to be sent at once, it was
possible to break a client by sending a reply to an other message sent
by the client. Eg:
- Write 8192 out of 11612 bytes of a workspace event.
- Blockingly write the reply to a workspace change message.
- Write the rest 3420 bytes of the workspace event.
This commit fixes this by utilizing the ipc queue for all types of
writes.
ipc_receive_message can only be called from a callback started in
ipc_new_client. This callback uses the same file descriptor with the
client also created in ipc_new_client. When the client is deleted, the
read callback is now also stopped. Thus, we can assume that whenever
ipc_receive_message is called, the corresponding client should still
exist.
- ipc_client now contains pointers to both write and read watchers. When
freed, a client will stop both of them.
- IPC_HANDLERs now work with ipc_clients instead of fds.
Fixes#3579.