1. Allow to use the line continuation, which is indicated by \ before the new line character, in config files.
2. Add a new testcase "247-config-line-continuation.t" for
a). testing line continuation
b). making sure string escaping still works
c). testing line continuations within a string
b). testing line continuations with too many lines
If the match expression is a plain number (e.g., '99'), the number of a workspace will be compared strictly. Otherwise, the match expression is taken as a regular expression and compared against the workspace's name.
This allows all of the following:
for_window [workspace=5] ...
for_window [workspace="5:foo"] ...
for_window [workspace="foo"] ...
fixes#1769
Fix TODO in bindings.c.
There is no problem to use atoi here since either keycode 0 or button0 is invalid.
But strtol is more flexible and is recommanded for conversion.
The format string set with "title_format" can contain the placeholder "%title" which will be replaced with the actual window title.
By not overwriting window->name itself, we make sure that assignment matching still works as expected.
fixes#1723
Try to detect base 16 numbers given to `con_id` and `id` for command criteria
by setting the base of strtol to 0. This should also detect octal.
This is necessary because mouse bindings now may be serialized as hex as of
5c32de4.
The comment immediately following implied that this was the intended
behaviour. Not doing so means that compound commands that both move a
window to a new workspace as well as do something that depends on the
workspace's geometry (e.g. 'move position center' or 'floating enable'
on a tiled window) would use the workspace's calloc'd 0x0+0x0 geometry.
When InputHint is not in WM_HINTS (i.e., the flag is not set), treat the window
as if the InputHint was set (the default behavior). This means that i3 will
focus the window when it becomes managed.
fixes#1676
%p is equivalent to either %x or %lx, depending on the pointer size of the
platform. Before this commit, we always used %d, which has the same behavior
on Linux, but is not automatically expanded to %ld on e.g. FreeBSD.
fixes#1661
Check if the `connection` of the randr output is
XCB_RANDR_CONNECTION_DISONNECTED and disable the output if it is.
This fixes an issue where the output would not be disabled if the output was
physically unplugged from the machine.
The Makefiles should put binaries in $(EXEC_PREFIX) and
architecture-independent files in $(PREFIX). Also a user may have a
prefixed- pkg-config, as in the case of cross compiling on Exherbo
Linux, so respect the well-accepted $(PKG_CONFIG) variable for this
purpose.
Outputs may disappear momentarily and come back later.
To prevent i3 from exit when no output is available momentarily, add a timeout delay_exit_on_zero_displays.
We only support unique marks, so looping over all matched windows must be prevented.
If more than one window is matched, we reject it with an error message.
fixes#1614
Introduce a config directive "show_marks [yes|no]" to en- or disable drawing marks on window decorations.
To not change the look & feel of existing configurations, the default is "no".
If a window has a mark set, e.g., "example", it will be printed on the right side of the window decorations.
The format is "[example]" and the name of the window is truncated if necessary.
Marks starting with an underscore ("_") will be ignored.
When a window receives a _NET_ACTIVE_WINDOW message, it can steal the focus. This may not be preferable to all users.
With this directive, the user can choose from one of the following:
1) 'smart' - focus the container if its workspace is visible, otherwise set the urgency flag (default)
2) 'urgent' - always set the urgency flag, do not steal focus
3) 'focus' - always switch focus, never set the urgency hint
4) 'none' - ignore the request entirely (do not switch focus, nor set the urgency hint)
fixes#1426
This option allows toggling marks on a window without knowing whether the mark is already set or not.
It behaves as follows:
1) If the matched window has no mark, the new mark is set.
2) If the matched window has another mark, the old mark is removed and the new mark is set.
3) If the matched window already has the mark, the mark is removed.
The behavior that all non-matched windows have this mark removed is kept.
fixes#1463
1. Add a function writeall and make swrite wrap that function. Use either writeall or swrite, depending on whether we want to exit on errors or not.
2. Fix warnings when compiling with a higher optimisation level.
(CFLAGS ?= -pipe -O3 -march=native -mtune=native -freorder-blocks-and-partition)
Signed-off-by: hwangcc <hwangcc@csie.nctu.edu.tw>
When an urgent container is moved to another workspace, the urgency hint
1) is unset on the source workspace and
2) set on the target workspace
fixes#1187
Handle changes to the property _NET_WM_STRUT_PARTIAL by reallocating
screen space in the dock area when the dock client requests a new
position.
This will allow changes to the bar config directive `position` to be
effective on the `reload` command.
fixes#1294