Try to detect base 16 numbers given to `con_id` and `id` for command criteria
by setting the base of strtol to 0. This should also detect octal.
This is necessary because mouse bindings now may be serialized as hex as of
5c32de4.
The comment immediately following implied that this was the intended
behaviour. Not doing so means that compound commands that both move a
window to a new workspace as well as do something that depends on the
workspace's geometry (e.g. 'move position center' or 'floating enable'
on a tiled window) would use the workspace's calloc'd 0x0+0x0 geometry.
When InputHint is not in WM_HINTS (i.e., the flag is not set), treat the window
as if the InputHint was set (the default behavior). This means that i3 will
focus the window when it becomes managed.
fixes#1676
%p is equivalent to either %x or %lx, depending on the pointer size of the
platform. Before this commit, we always used %d, which has the same behavior
on Linux, but is not automatically expanded to %ld on e.g. FreeBSD.
fixes#1661
Check if the `connection` of the randr output is
XCB_RANDR_CONNECTION_DISONNECTED and disable the output if it is.
This fixes an issue where the output would not be disabled if the output was
physically unplugged from the machine.
The Makefiles should put binaries in $(EXEC_PREFIX) and
architecture-independent files in $(PREFIX). Also a user may have a
prefixed- pkg-config, as in the case of cross compiling on Exherbo
Linux, so respect the well-accepted $(PKG_CONFIG) variable for this
purpose.
Outputs may disappear momentarily and come back later.
To prevent i3 from exit when no output is available momentarily, add a timeout delay_exit_on_zero_displays.
We only support unique marks, so looping over all matched windows must be prevented.
If more than one window is matched, we reject it with an error message.
fixes#1614
Introduce a config directive "show_marks [yes|no]" to en- or disable drawing marks on window decorations.
To not change the look & feel of existing configurations, the default is "no".
If a window has a mark set, e.g., "example", it will be printed on the right side of the window decorations.
The format is "[example]" and the name of the window is truncated if necessary.
Marks starting with an underscore ("_") will be ignored.
When a window receives a _NET_ACTIVE_WINDOW message, it can steal the focus. This may not be preferable to all users.
With this directive, the user can choose from one of the following:
1) 'smart' - focus the container if its workspace is visible, otherwise set the urgency flag (default)
2) 'urgent' - always set the urgency flag, do not steal focus
3) 'focus' - always switch focus, never set the urgency hint
4) 'none' - ignore the request entirely (do not switch focus, nor set the urgency hint)
fixes#1426
This option allows toggling marks on a window without knowing whether the mark is already set or not.
It behaves as follows:
1) If the matched window has no mark, the new mark is set.
2) If the matched window has another mark, the old mark is removed and the new mark is set.
3) If the matched window already has the mark, the mark is removed.
The behavior that all non-matched windows have this mark removed is kept.
fixes#1463
1. Add a function writeall and make swrite wrap that function. Use either writeall or swrite, depending on whether we want to exit on errors or not.
2. Fix warnings when compiling with a higher optimisation level.
(CFLAGS ?= -pipe -O3 -march=native -mtune=native -freorder-blocks-and-partition)
Signed-off-by: hwangcc <hwangcc@csie.nctu.edu.tw>
When an urgent container is moved to another workspace, the urgency hint
1) is unset on the source workspace and
2) set on the target workspace
fixes#1187
Handle changes to the property _NET_WM_STRUT_PARTIAL by reallocating
screen space in the dock area when the dock client requests a new
position.
This will allow changes to the bar config directive `position` to be
effective on the `reload` command.
fixes#1294
This introduces a "separator_symbol" property for the i3bar configuration.
If set, the specified string will be used as a separator instead of a vertical line. Since it is an optional configuration, complete backwards compatibility is given.
fixes#1472
Otherwise, placeholder windows would accumulate these over restarts. The
worst part is that they don’t get dumped properly, meaning an empty
swallows specification ends up in the state, which matches any window,
so other random windows would be matched into the placeholder (e.g.
i3bar).
fixes#1502
This reverts commit cbd51ce664.
If you’ve started using this feature, I’m very sorry, but I think it’s
better to revert it entirely, as it will only cause more problems in the
future as more and more people upgrade and get bitten by this if we
didn’t revert it…
fixes#1536
When renaming a workspace on another output that moves the workspace to
the current output, the renamed workspace would be shown even though it
does not contain the focused container.
Explicitly show the focused workspace after the move. This is necessary
because `workspace_move_to_output` will show the workspace that is
moved.
Before this commit, placeholder windows had any matches that were
defined in the JSON file, _followed_ by an i3-internal match that
ensures the placeholder X11 window gets swallowed into the placeholder
i3 container.
The problem was that the first successful match was deleted, and if
users specified a criterion (title=IPython) that matched the placeholder
window itself (name=IPython), then that match is deleted and the
i3-internal match is kept. This results in the actual window the user
wants to match not being swallowed, and the placeholder window not
displaying any criteria.
fixes#1526